Inquiry For Liaison Service
Sector abcAir Transport Tender ValueN.A.
LocationDelhi - India Ref.No56344067
Closing Date21 - Mar - 2023
Supply of design, supply, installation, testing and commissioning (dsitc) of grid connected ground mounted dc solar pv-module-based power supply system of capacity below mentioned with modules fixed in anodized aluminium frame complete as required including elevated structural support systems for all components after proper soil investigation / treatment as per site conditions, modular inverters with atleast 25 percent standby / spare capacity with required communication / data / control / power cables, safety system for reverse power protection, min ip65 rated dc db / jb for connection of modules to inverters . . . . . . solar power plant complete as required and as per technical specifications and other terms and conditions of the contract. it also includes provision of skilled / unskilled manpower as per the requirement (as and when required) for proper operation and routine maintenance of the said solar power plant during defects liability period (dlp) of 02 years as per specifications, terms and conditions of the tender document., it also includes o and aicmc of above said solar power plant for 08 years after expiry of dlp of 02 years as per tender specifications, terms and conditions etc. completed as required., note -, the quoted rates are inclusive of 08 years of operation and aicmc cost (after dlp period of 02 years). the share of o and aicmc and dsitc components are fixed. the o and aicmc component shall be 10 percent of quoted amount and dsitc component shall be 90 percent of the quoted amount., distribution of 10 percent . . . . . ., location - udaipur airport , capacity - 500 kw (ac), approx. distance of evacuation point from solar installation - 2.5 km, evacuation point voltage level - 33 kv (as per system design and site requirement), note - for details refer tender document schedule of quanties page soq 1", "design supply, installation, testing and commissioning (dsitc) of grid connected ground mounted dc solar pv-module-based power supply system of capacity below mentioned with modules fixed in anodized aluminium frame complete as required including elevated structural support systems for all components after proper soil investigation / treatment as per site conditions, modular inverters with atleast 25 percent standby / spare capacity with required communication / data / control / power cables, safety system for reverse power protection, min ip65 rated dc db / jb for connection of modules to inverters . . . . . . solar power plant complete as required and as per technical specifications and other terms and conditions of the contract. it also includes provision of skilled / unskilled manpower as per the requirement (as and when required) for proper operation and routine maintenance of the said solar power plant during defects liability period (dlp) of 02 years as per specifications, terms and conditions of the tender document., it also includes o and aicmc of above said solar power plant for 08 years after expiry of dlp of 02 years as per tender specifications, terms and conditions etc. completed as required., note , the quoted rates are inclusive of 08 years of operation and aicmc cost (after dlp period of 02 years). the share of o and aicmc and dsitc components are fixed. the o and aicmc component shall be 10 percent of quoted amount and dsitc component shall be 90 percent of the quoted amount., distribution of 10 percent . . . . . , location - jabalpur airport , capacity - 500 kw (ac), approx. distance of evacuation point from solar installation - 0.5 km, evacuation point voltage level - ht / lt (as per system design and site requirement), note - for details refer tender document schedule of quanties page soq 2", "design supply, installation, testing and commissioning (dsitc) of grid connected ground mounted dc solar pv-module-based power supply system of capacity below mentioned with modules fixed in anodized aluminium frame complete as required including elevated structural support systems for all components after proper soil investigation / treatment as per site conditions, modular inverters with atleast 25 percent standby / spare capacity with required communication / data / control / power cables, safety system for reverse power protection, min ip65 rated dc db / jb for connection of modules to inverters . . . . . . . solar power plant complete as required and as per technical specifications and other terms and conditions of the contract. it also includes provision of skilled / unskilled manpower as per the requirement (as and when required) for proper operation and routine maintenance of the said solar power plant during defects liability period (dlp) of 02 years as per specifications, terms and conditions of the tender document., it also includes o and aicmc of above said solar power plant for 08 years after expiry of dlp of 02 years as per tender specifications, terms and conditions etc. completed as required., note -, the quoted rates ar
If you are a new user, then please register, it's Free and then fill the form below.

If you are registered with us, just fill the form below, we will get back to you shortly.


All fileds marked with '*' are compulsary.
Email Id : *
Comments: *
 Login/Register
Members/Visitors Login to continue
 Email Id:
 Password:


 Forgot Password?
 Tenders by Industry
Skip Navigation Links.
Expand Power Plant TendersPower Plant Tenders
more  »
Tenders by Ownership
Central Government/Public Sector Tenders
Co-operatives Tenders
Corporations/ Associations/ Others Tenders
Education & Research Institutes Tenders
Joint Sector Tenders
Non classified Tenders
Private Sector Tenders
Research Institutes Tenders
State Government Tenders
Trust Tenders
 Tenders by State in India
Andhra Pradesh Tenders
Delhi Tenders
Gujarat Tenders
Madhya Pradesh Tenders
Maharashtra Tenders
Rajasthan Tenders
Tamil Nadu Tenders
Uttar Pradesh Tenders
West Bengal Tenders
more  »